3 GENERAL PRINCIPLES OF DESIGN, CONSTRUCTION AND CLEANING FOR ALL BAKERY EQUIPMENT
The following general principles of design, construction, and cleaning shall apply to all
equipment covered in this standard, except where exemption from compliance is specifically stated in
the Special Principles of Design and Construction in each section relating to individual types of
equipment. Particular attention is called to accessories, such as pumps, valves, pipe couplings and
thermometers, which may be an integral part of the equipment.
3.1 Product Zone
3.1.1 All surfaces shall be smooth, except where a textured surface is required for the process.
3.1.2 All surfaces should be readily accessible or readily removable, and shall be accessible
or removable.
3.1.3 All surfaces shall be non-toxic.
3.1.4 All surfaces shall be non-absorbent or cleanable if required for the process.
3.1.5 All surfaces shall be of corrosion-resistant material in their intended area of use and
cleaning.
3.1.6 Dissimilar materials shall not be used where electrolytic corrosion may take place
during use or during exposure to their normal cleaning materials.
3.1.7 Cadmium or antimony shall not be used.
3.1.8 Wood shall not be used.
3.1.9 Lead and tin alloy solder shall not be used.
3.1.10 Copper, brass, monel and other copper alloys shall not be used where edible oils,
liquid shortening, chocolate liquor and other fatty food products come in contact with the metal.
3.1.11 Permanently joined metal surfaces shall be butted and welded, brazed or silver
soldered, and finished flush and equal to surrounding area. Types of chemical adhesives, which are
non-toxic, and the use of which results in a joint of sufficient mechanical strength for the purpose
intended are permissible.
3.1.12 Permanently joined surfaces with a total included internal angle less than 135 degrees
shall have a radius of not less than ¼ inch (6mm) tangential to both adjacent surfaces.
3.1.13 Bearings should be outside the product zone and should be sealed or self-lubricating.
Bearings or other surfaces requiring lubrication in the product zone shall conform to the requirements
of Sections 3.1.1, 3.1.2 and 3.1.3, and lubricants shall be of food grade material. Bearings
requiring other than edible lubrication shall be outside the product zone, and the design and
construction of these shall be such that lubricant cannot leak, drip or be forced into the product
zone.
3.1.14 Seals shall be non-toxic, non-absorbent, non-exuding, self-lubricating and smooth, and
shall not affect or be affected by the product, ingredients or cleaning compounds. Seals shall be
removable.
3.1.15 Belting, other than metal, shall be coated, impregnated or made of odorless, non-toxic
and non-absorbent material. Where the process requires a non-coated belt, it shall be cleanable or
replaceable.
3.1.16 Gaskets shall be non-toxic, non-absorbent and non-exuding, and shall not affect or be
affected by the product, ingredients, or cleaning compounds, and shall be installed in a manner which
results in a true fit to prevent protrusion in the product zone or creation of recesses or ledges
between the gasketed joints.
3.1.17 Hinges and latches shall be of the simple, take-apart type, and shall be so constructed
that when taken apart no cracks or crevices exist.
3.1.18 Inspection windows and light ports shall be of shatter-resistant material. They shall
be sealed or readily removable.
3.1.19 Air or other gases mechanically introduced into the product or product zone shall be
filtered or washed to remove particles 5 microns or larger, and shall not contain oil, water and other
liquids, unless such materials are specifically required as an operational procedure. Air within the
bakery delivered by small centrifugal blowers at pressures less than 10 inches (250mm) water column
shall be filtered or washed to remove particles 50 microns or larger. All air for comfort ventilation
shall be conditioned only to the extent required by regulatory agencies.
3.1.20 Covers shall be of the overlapping type and if they are in two or more parts, they
shall be designed with drip protectors. Hinged covers shall pivot outboard.
3.1.21 Dead ends shall not be permitted.
3.1.22 Thermometers and sensor measuring devices shall be designed to prevent contamination by
any portion of the measuring elements. Where protecting wells are provided, weep holes shall be
provided and shall drain to the outside of the product zone. Mercury or other toxic materials shall
not be used in product zones unless enclosed within a corrosion resistant well or case which drains to
the outside of the product zone.
3.1.23 Tracks and guides for doors, covers and access panels shall be designed and constructed
so as to minimize retention of food particles, condensation, spillage and soil.
3.1.24 Bottom guides for sliding doors shall have sufficient opening to facilitate cleaning
and drainage. Bottom guide grooves shall have open ends.
3.1.25 Surfaces shall be made of odorless materials.
3.2 Non-Product Zone
3.2.1 All surfaces, unless sealed, shall be accessible or removable for cleaning.
3.2.2 All materials shall be suitable for the purpose intended and shall conform to the
requirements of cleanability.
3.2.3 All surfaces, including joints and surfaces of insulation unless sealed, shall be
cleanable and impervious to moisture.
3.2.4 Screws, bolt heads, nuts, rivets and similar projections shall not form pockets or
areas difficult to clean.
3.2.5 All joints and edges where two members are permanently joined shall be joined in such
a manner as to minimize horizontal ledges, cracks, crevices and protrusions.
3.2.6 Equipment other than that on solid bases sealed to the floor shall provide a floor
clearance of at least 6 inches (150mm) or shall be accessible for cleaning. Structural members shall
be arranged so as not to form traps, recesses or pockets. If made of hollow stock, frame members
shall have the ends closed.
3.2.7 Guards shall either be hinged or removable or shall be fitted with covers that are
either hinged or removable. All guards shall be constructed so that transient fluids, splash and
spillage will not be retained.
3.2.8 Permanently joined surfaces having interior angles shall be accessible and should be
curved, rounded or cove-shaped with not less than 1/16 inch (1.5mm) minimum radius or curvature.
3.2.9 Where lubrication is required, the design and construction shall be such that the
lubricant cannot leak, drip or be forced into the product zone.
3.2.10 Name plates shall be sealed to the surface.
3.2.11 Motors and accessory equipment shall be mounted with at least 2 inches (50mm) minimum
space on all sides, top and bottom of the motor or motor and accessory to allow cleaning around the
motor or motor and accessory.
3.2.12 Face-flange or base-mounted motors or accessory equipment with machined surfaces are
permitted.
3.2.13 The electrical wiring system shall be constructed so that dust shall not enter. When
located in a wet or washdown area, the electrical system shall be constructed so that liquids shall
not enter.
3.2.14 All electrical enclosures shall be sealed to the mounting surface and any adjacent
surface, or shall be spaced away at least ¾ inch (20mm) or at a distance equal to one-fifth of the
shortest dimension of the electrical enclosure parallel to the surface, whichever is greater, but not
necessarily more than 18 inches (460mm) to allow for adequate access for cleaning. Hinges on
electrical panels are exempt from Section 3.1.17.
3.2.15 Conduits shall be installed so that hard-to-clean areas or crevices are not formed, or
shall be spaced away from adjacent surfaces at least ¾ inch (20mm) to allow for cleaning. Flexible
conduit and fittings shall be liquid-tight.
3.2.16 Hollow spaces within the frame, which do not contain functional parts, shall be sealed. Hollow spaces within the frame, which contain functional parts, shall be sealed or closed, and readily accessible.
3.2.17 All light bulbs, lamps and tubes shall be protected against falling, and shall be
shatter-resistant, housed in shatter-resistant fixtures, or otherwise protected against breakage.
3.2.18 Inspection windows and light ports shall be of shatter-resistant material. They shall
be sealed.
3.2.19 Tracks and guides for doors, covers and access panels shall be designed and constructed
so as to minimize retention of food particles, condensation, spillage and soil.
3.2.20 Bottom guides for sliding doors shall have sufficient opening to facilitate cleaning
and drainage. Bottom guide grooves shall have open ends.
3.2.21 The frame and/or base of the equipment shall be so designed that areas difficult to
clean are not created when the equipment is installed.
3.2.22 Surfaces shall be corrosion-resistant and non-absorbent, or shall have a protective
coating.
3.2.23 Surfaces shall be made of odorless materials.
3.3 Cleaning of Equipment
3.3.1 Written Instructions: Written instructions as supplied by the equipment manufacturers
shall be incorporated into training programs and made readily available to operating, maintenance and
sanitation personnel. Note that the same person may perform operation, maintenance and/or sanitation
tasks.
3.3.2 Cleaning Personnel: Sanitation and cleaning personnel shall be restricted to properly
trained, designated and instructed employees. It is the responsibility of the employer to train
sanitation and cleaning personnel in the performance of their responsibilities.
|
|